Customization: | Available |
---|---|
Type: | Fiber Optic Splitter&Coupler |
Wiring Devices: | ODF |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Description
ABS Module PLC Splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. Fiberlink provides whole series of 1xN splitter and 2xN splitter products that are tailored for specific applications. All ABS Module Splitters meet GR-1209-CORE-2001 and GR-1221-CORE-1999 requirements.
Port Configuration | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | |
Fiber Type | SMF28-e or customer specified | ||||||
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typical | 3.7 | 6.8 | 10.0 | 13.0 | 16.0 | 19.5 |
Max | 4.0 | 7.2 | 10.5 | 13.5 | 16.9 | 21.0 | |
Loss Uniformity(dB) | Max | 0.4 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 |
Return Loss (dB) | Min | 50 | 50 | 50 | 50 | 50 | 50 |
Polarization Dependent Loss(dB) | Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 |
Directivity (dB) | Min | 55 | 55 | 55 | 55 | 55 | 55 |
Wavelength Dependent Loss(dB) | Max | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.8 |
Temperature Stability (-40~85 ºC)(dB) |
Max | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
Operating Temperature (ºC) | -40~85 | ||||||
Storage Temperature (ºC) | -40~85 | ||||||
Package Size (mm) | 40x4x4 | 50x4x4 | 50x7x4 | 60x12x4 |
Note: All the data above does not include connectors.
Add an additional 0.2dB loss per connector.Port Configuration | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | |
Fiber Type | SMF28-e or customer specified | ||||||
Operating Wavelength (nm) | 1260~1650 | ||||||
Insertion Loss (dB) | Typical | 3.8 | 7.4 | 10.8 | 14.2 | 17.0 | 21.0 |
Max | 4.2 | 7.8 | 11.2 | 14.6 | 17.5 | 21.5 | |
Loss Uniformity(dB) | Max | 1.0 | 1.4 | 1.5 | 2.0 | 2.5 | 2.5 |
Return Loss (dB) | Min | 50 | 50 | 50 | 50 | 50 | 50 |
Polarization Dependent Loss(dB) | Max | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.5 |
Directivity (dB) | Min | 55 | 55 | 55 | 55 | 55 | 55 |
Wavelength Dependent Loss(dB) | Max | 0.8 | 0.8 | 0.8 | 0.8 | 0.8 | 1.0 |
Temperature Stability (-40~85 ºC)(dB) |
Max | 0.5 | 0.5 | 0.5 | 0.8 | 0.8 | 1.0 |
Operating Temperature (ºC) | -40~85 | ||||||
Storage Temperature (ºC) | -40~85 | ||||||
Package Size (mm) | 40x4x4 | 50x7x4 | 60x7x4 | 60x12x4 |
Note: All the data above does not include connectors.
Add an additional 0.2dB loss per connector.FPA | XXX | X | XX | X | XX | X | X |
Port Configuration | Input Fiber Type | Intput Fiber Length | Output Fiber Type | Output Fiber Length | Input Connector | Output Connector | |
F=Fiberlink | 102=1x2 | B= 250um Bare Fiber | 10= 1.0m | B= 250um Bare Fiber | 10= 1.0m | 0=None | 0=None |
P=PLC | 104=1x4 | L= 900um Loose tube | 15= 1.5m | R= Ribbon Fiber | 15= 1.5m | 1=FC/UPC | 1=FC/UPC |
A=ABS Module | 108=1x8, | T= 900um Tight buffer | 20= 2.0m | F= Fan out Box with 900um loose tube | 20= 2.0m | 2-FC/APC | 2-FC/APC |
116=1x16 | … … | 3=SC/UPC | 3=SC/UPC | ||||
132=1x32 | 4=SC/APC | 4=SC/APC | |||||
164=1x64 | 5=LC/UPC | 5=LC/UPC | |||||
202=2x2 | 6=LC/APC | 6=LC/APC | |||||
204=2x4 | X=customized | X=customized | |||||
208=2x8, | |||||||
216=2x16 | |||||||
232=2x32 |