Customization: | Available |
---|---|
Type: | OTDR Tester |
Wiring Devices: | Integrated Wiring |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical Specifications1 | ||||||||||
Wavelength (nm) | 850/1300 | 1310/1550 | 1310/1490/1550 | 1625 | ||||||
Dynamic range (dB)2 | 23/21 | 32/30 | 38/36 | 32/30/30 | 344 | 365 | ||||
Pulse width (ns) | 5,20,40,80,160,320,640,1280 | 5,20,40,80,160,320,640,1280,2560,5120,10240,20480 | ||||||||
Event blind zone (m)3 | 3m | 3m | ||||||||
Attenuation blind zone (m)3 | 13m | 13m | ||||||||
Linearity (dB/dB) | ±0.05 dB/ dB | |||||||||
Loss threshold (dB) | 0.05 | |||||||||
Loss resolution ratio (dB) | 0.01 | |||||||||
Sampling resolution ratio (m) | 0.125 to 8 | |||||||||
Sampling point | 32K | |||||||||
Distance uncertainty (m) | ±(1 m + 5×10-5× distance + sampling interval) | |||||||||
Distance scope (km) | 0.3 to180 | |||||||||
Typical real-time refreshing duration (s) | 0.2 | |||||||||
Memory capacity of trace | SD Card (4G), > 10000 pieces | |||||||||
Duration of measurement | Defined by user; 5sec, 10sec, 15sec, 30sec, 1min, 2min, and 3min are se lectable |
|||||||||
General specification | Interface category | |||||||||
Dimension (H×W×D) | 150×235×66 | Optical interface | FC/UPC (PC, and APC are selectable) | |||||||
Weight | 1.5kg | Data interface | USB interface, SD card interface | |||||||
Temperature | Running temperature -10ºC to 50ºC | |||||||||
Memory temperature -40ºC to 70ºC | Visible failure orientation VFL | |||||||||
Relative humidity | 0% to 95% (non condensation) | Wavelength | 650nm | |||||||
Power supply | Lithium battery; continuing working duration ≥ 8 hours | Output power (dBm) | ≥-3 | |||||||
Warranty period | 12 months | Maximum testing distance | 3km | |||||||
Remarks: 1. The technical specification describes the ensured performance of the instrument when using typical PC model connector to measure. Without considering the uncertainty caused by optical fiber refractivity. 2. Dynamic range is the data measured under the condition of the maximum pulse width and 3 minutes of average time. Dynamic range is the data measured under the condition of 180km/20480ns/3min. 3. Measuring conditions of blind zone: reflection event is within 4Km, reflection strength < -35dB. Measured by the minimum pulse width. 4. Dynamic range measured when there is filter. 5. Dynamic range measured when there is no filter. |
Question:Can I have a sample before place an order?
Yes,of course we will provide free samples if value is cheap.but without shipping charges.
Question:What about the leadtime?
Around 7-14 days normally
Question:How about the MOQ?
500pcs normally per color for Fiber cable.consult sales if needed.
Question:Which mode of transportstion?
UPS/DHL/TNT/Fedex/Aramex/Sea/Air and so on.
Question:Can I put logo on the products?
Yes,of course,we do OEM and ODM aslo.
Question:what is the delivery terms?
EXW or FOB is our main delivery term.