Customization: | Available |
---|---|
Application: | Communication, Sensor, Probe |
Type: | Single-mode Fiber |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Cable Type | Layer Cable | ||||||||||
Fiber count | 12 | 24 | 36 | 48 | 60 | 72 | 96 | 144 | |||
Number of loose tube | 1 | 2 | 3 | 4 | 5 | 6 | 8 | 12 | |||
Number of filled string | 5 | 4 | 3 | 2 | 1 | 0 | 0 | 0 | |||
Number of fiber/tube | 12 | ||||||||||
Water blocking method | FRP or PE lining | Water Blocking yam | |||||||||
Cable Core | Water Blocking yam | ||||||||||
Thickness of HDPE sheath | Nominal:0.5mm, Average: 0.45mm, Minimum:0.4mm | ||||||||||
Overall Diameter | 5.6±0.1mm, | 6.4±0.1mm | 7.8±0.1mm | ||||||||
Weight | 27kg/km | 40kg/km | 55kg/km | ||||||||
Max.Tensile Strength | 500N | 1000N | 1000N | ||||||||
Max.Crushing Resistance | 800N/100mm | ||||||||||
Min.Bending radius -Static | 12 outer Ф | ||||||||||
Min.Bending radius -Dynamic | 20 outer Ф | ||||||||||
Cable Fiber Attenuation (single mode) | 0.35dB/km max@1310nm 0.22dB/km max@1550nm | ||||||||||
Temperature range | Storage -40~+70ºC; Installation -10~+40ºC; Operation -40~+70ºC | ||||||||||
Cable service lifer (estimate value) | 25 years |
Blowing Tool | Typical blowing length | ||
PLUMETTAZ:PR-140,MiniJet-400 etc. Air pressure: 15 bar |
Fiber Count | Duct type 8.0/10.0mm | Duct type 10.0/12.0mm |
12-72 fibers | ≥1800m | ≥2300m | |
96 fibers | ≥1800m | ≥2300m | |
144 fibers | / | ≥1200m |
Item | Testing Method | Testing Results | Specified Value |
Tension Performance | IEC 60794-1-2-E1 | Short term:Δa<0.10dB,Δa reversible; Long term: Δa ≤0.03dB |
Short term: see technical index Long term=0.5 Short term |
Crush | IEC 60794-1-2-E3 | Short term:Δa<0.10dB,Δa reversible; Long term: Δa ≤0.03dB The outer sheath has no visible crack. |
Short term: crushing force=800N Long term: crushing force=400N |
Repeated bending | IEC 60794-1-2-E6 | After test,Δa ≤0.03dB, The outer sheath has no visible crack | R=20outer Ф |
Bending load=50N | |||
Bending times=30 | |||
Torsion | IEC 60794-1-2-E7 | After test,Δa ≤0.03dB, The outer sheath has no visible crack | Torsion angle = ±180ºC |
Torsion load=50N | |||
Torsion times=10 | |||
Cable bend | IEC 60794-1-2-E11A | After test, The optical fiber can't be broken; the outer sheath has no visible crack | R=20 outer Ф 10 Turns Cycles times=5 |
All optical testing proceeded at 1550nm |
Item | Testing Method | Testing Results |
Temperature cycling | IEC 60794-1-2-F1 | Allowable additional attenuation (1550nm) |
G.652D/G657 | ||
Δa ≤0.05dB/km,Δa Reversible | ||
Water penetration | IEC 60794-1-2-F5B | water column;1m,3m cable,Period:24 hours No water leak through the open end of cable |
Filling compound flow | IEC 60794-1-2--E14 | 70ºC , Period: 24 hours No compound flow from the cable |
P/N | Fiber count | Nominal diameter | Nominal weight | Max tensile strength | Temperature |
ABMD-12G652D-PE | 12F | 5.2±0.1mm | 25(kg/km) | 500N | -40 to +70ºC |
ABMD-24G652D-PE | 24F | 5.2±0.1mm | 25(kg/km) | 500N | |
ABMD-36G652D-PE | 36F | 5.2±0.1mm | 25(kg/km) | 500N | |
ABMD-48G652D-PE | 48F | 5.2±0.1mm | 25(kg/km) | 500N | |
ABMD-60G652D-PE | 60F | 5.2±0.1mm | 25(kg/km) | 500N | |
ABMD-72G652D-PE | 72F | 5.2±0.1mm | 25(kg/km) | 500N | |
ABMD-96G652D-PE | 96F | 6.1±0.1mm | 35(kg/km) | 1000N | |
ABMD-144G652D-PE | 144F | 7.9±0.1mm | 57(kg/km) | 1200N |